Skip to content

Zigbee2MQTT

References

Definitions

  • "compose file" means the file at the path:

    ~/IOTstack/docker-compose.yml
    

Basic process for new users

  1. Run the IOTstack menu and choose both "Mosquitto" and "Zigbee2MQTT". That adds the service definitions for both of those containers to your compose file.

  2. Prepare your Zigbee adapter by flashing its firmware.

  3. Follow the steps in Identify your Zigbee adapter to work out how your adapter "mounts" on your Raspberry Pi, and edit your compose file to include that information.
  4. The default environment variables assume:

    • You are running Mosquitto and Zigbee2MQTT as IOTstack containers on the same computer; and
    • You want the Zigbee2MQTT web front end to be available on port 8080.

    This is a good basis for getting started. If it sounds like it will meet your needs, you will not need to make any changes. Otherwise, review the environment variables and make appropriate changes to the service definition in your compose file.

  5. Bring up your stack:

    $ cd ~/IOTstack
    $ docker-compose up -d
    
  6. Confirm that the Zigbee2MQTT container appears to be working correctly. You should:

  7. Connect to the web front end and start adding your Zigbee devices.

Prepare your Zigbee adapter

Zigbee adapters usually need to be "flashed" before they can be used by Zigbee2MQTT. To prepare your adatper:

  1. Go to the supported adapters page.
  2. Find your adapter in the list.
  3. Follow the instructions for flashing your adapter.

Note:

  • If you can't find your adapter in the list of supported devices, you may not be able to get the Zigbee2MQTT container to connect to it. This kind of problem is outside the scope of IOTstack. You will have to raise the issue with the Zigbee2MQTT project.

Identify your Zigbee adapter

This section covers adapters that connect to your Raspberry Pi via USB.

See connect to a remote adapter for information on connecting to adapters via TCP.

Many USB Zigbee adapters mount as /dev/ttyACM0 but this is not true for all adapters. In addition, if you have multiple devices connected to your Raspberry Pi that contend for a given device name, there are no guarantees that your Zigbee adapter will always be assigned the same name each time the device list is enumerated.

For those reasons, it is better to take the time to identify your Zigbee adapter in a manner that will be predictable, unique and reliable:

  1. If your Zigbee adapter is connected to your Raspberry Pi, disconnect it.
  2. Run the following command (the option is the digit "1"):

    $ ls -1 /dev/serial/by-id
    

    The possible response patterns are:

    • An error message:

      ls: cannot access '/dev/serial/by-id': No such file or directory
      
    • A list of one or more lines where your Zigbee adapter is not present. Example:

      usb-Silicon_Labs_CP2102N_USB_to_UART_Bridge_Controller_f068b8e7e82d4b119c0ee71fa1143ea0-if00-port0
      

    The actual response (error, or a list of devices) does not matter. You are simply establishing a baseline.

  3. Connect your prepared Zigbee adapter to a USB port on your Raspberry Pi.

  4. Repeat the same ls command from step 2. The response pattern should be different from step 2. The list should now contain your Zigbee adapter. Example:

    usb-Silicon_Labs_CP2102N_USB_to_UART_Bridge_Controller_f068b8e7e82d4b119c0ee71fa1143ea0-if00-port0
    usb-Texas_Instruments_TI_CC2531_USB_CDC___0X00125A00183F06C5-if00
    

    The second line indicates a CC2531 adapter is attached to the Raspberry Pi.

    If the response pattern does not change, it means the Raspberry Pi is unable to see your adapter. The two most common reasons are:

    1. Your adapter was not flashed correctly. Start over at prepare your Zigbee adapter.
    2. Your adapter does not mount as a serial device. Try repeating steps 2 through 4 with the command:

      $ ls -1 /dev
      

      to see if you can discover how your adapter attaches to your Raspberry Pi.

      One example is the Electrolama zig-a-zig-ah which attaches as /dev/ttyUSB0.

  5. Use the output from the ls command in step 4 to form the absolute path to your Zigbee adapter. Example:

    /dev/serial/by-id/usb-Texas_Instruments_TI_CC2531_USB_CDC___0X00125A00183F06C5-if00
    
  6. Check your work like this (the option is the lower-case letter "l"):

    $ ls -l /dev/serial/by-id/usb-Texas_Instruments_TI_CC2531_USB_CDC___0X00125A00183F06C5-if00
    lrwxrwxrwx 1 root root 13 Mar 31 19:49 dev/serial/by-id/usb-Texas_Instruments_TI_CC2531_USB_CDC___0X00125A00183F06C5-if00 -> ../../ttyACM0
    

    What the output is telling you is that the by-id path is a symbolic link to /dev/ttyACM0. Although this may always be true on your Raspberry Pi, the only part that is actually guaranteed to be true is the by-id path, which is why you should use it.

  7. Once you have identified the path to your adapter, you communicate that information to docker-compose like this:

    $ echo ZIGBEE2MQTT_DEVICE_PATH=/dev/serial/by-id/usb-Texas_Instruments_TI_CC2531_USB_CDC___0X00125A00183F06C5-if00 >>~/IOTstack/.env
    

    Note:

    • if you forget to do this step, docker-compose will display the following error message:

      parsing ~/IOTstack/docker-compose.yml: error while interpolating services.zigbee2mqtt.devices.[]: required variable ZIGBEE2MQTT_DEVICE_PATH is missing a value: eg echo ZIGBEE2MQTT_DEVICE_PATH=/dev/ttyACM0 >>~/IOTstack/.env
      
  8. Continue from bring up your stack.

Configuration

Environment variables

Any value that can be set in a Zigbee2MQTT configuration file can also be set using an environment variable.

The Zigbee2MQTT documentation explains the syntax.

Note:

  • Do not use quote marks to enclose the values (right hand sides) of environment variables.

Whenever you change the value of an environment variable, you also need to tell docker-compose to apply the change:

$ cd ~/IOTstack
$ docker-compose up -d zigbee2mqtt

The default service definition provided with IOTstack includes the following environment variables:

  • ZIGBEE2MQTT_CONFIG_MQTT_SERVER=mqtt://mosquitto:1883

    Typical values for this are:

    • mqtt://mosquitto:1883

      This is default value supplied with the IOTstack template. It assumes that both Zigbee2MQTT and the Mosquitto broker are running in non-host mode containers on the same Raspberry Pi.

    • mqtt://localhost:1883

      This would be appropriate if you were to run Zigbee2MQTT in host mode and the Mosquitto broker was running on the same Raspberry Pi.

    • mqtt://«host-or-ip»:1883

      If the Mosquitto broker is running on a different computer, replace «host-or-ip» with the IP address or domain name of that other computer. You should also remove or comment-out the following lines from the service definition:

      depends_on:
        - mosquitto
      

      The depends_on clause ensures that the Mosquitto container starts alongside the Zigbee2MQTT container. That would not be appropriate if Mosquitto was running on a separate computer.

  • ZIGBEE2MQTT_CONFIG_FRONTEND=true

    This variable activates the Zigbee2MQTT web interface on port 8080. If you want to change the port number where you access the Zigbee2MQTT web interface, see connecting to the web GUI.

  • ZIGBEE2MQTT_CONFIG_ADVANCED_LOG_SYMLINK_CURRENT=true

    Defining this variable causes Zigbee2MQTT to create a symlink pointing to the current log folder at the path:

    ~/IOTstack/volumes/zigbee2mqtt/data/log/current
    

    See Checking the log for more information about why this is useful.

  • - DEBUG=zigbee-herdsman*

    Enabling this variable turns on extended debugging inside the container.

Configuration file

Zigbee2MQTT creates a default configuration file at the path:

~/IOTstack/volumes/zigbee2mqtt/data/configuration.yaml

Although you can edit the configuration file, the approach recommended for IOTstack is to use environment variables.

If you decide to edit the configuration file:

  1. You will need to use sudo to edit the file.
  2. After you have finished making changes, you need to inform the running container by:

    $ cd ~/IOTstack
    $ docker-compose restart zigbee2mqtt
    
  3. Check the log for errors.

Note:

  • If you start Zigbee2MQTT from a clean slate (ie where the configuration file does not exist) and your compose file does not define the … MQTT_SERVER environment variable discussed above, the container will go into a restart loop. This happens because the Zigbee2MQTT container defaults to trying to reach the Mosquitto broker at localhost:1883 instead of mosquitto:1883. That usually fails.

Verifying basic operation

Checking status

$ docker ps | grep -e mosquitto -e zigbee2mqtt
NAMES         CREATED          STATUS
zigbee2mqtt   33 seconds ago   Up 30 seconds
mosquitto     33 seconds ago   Up 31 seconds (healthy)

The above output is filtered down to the relevant columns

You are looking for evidence that the container is restarting (ie the "Status" column only ever shows a low number of seconds when compared with the "Created" column).

Checking the log

You can't use docker logs zigbee2mqtt to inspect the Zigbee2MQTT container's logs. That's because Zigbee2MQTT writes its logging information to the path:

~/IOTstack/volumes/zigbee2mqtt/data/log/yyyy-mm-dd.hh-mm-ss/log.txt

where yyyy-mm-dd.hh-mm-ss is the date and time the container was last started. This means that you have to identify the folder with the latest timestamp before you can inspect the log contained within it.

Fortunately, Zigbee2MQTT offers a shortcut. If the … LOG_SYMLINK_CURRENT environment variable is true then the path to the current log will be:

~/IOTstack/volumes/zigbee2mqtt/data/log/current/log.txt

You can use commands like cat and tail to examine the current log. Example:

$ cat ~/IOTstack/volumes/zigbee2mqtt/data/log/current/log.txt

Checking Mosquitto connectivity

To perform this check, you will need to have the Mosquitto clients installed:

$ sudo apt install -y mosquitto-clients

The Mosquitto clients package includes two command-line tools:

  • mosquitto_pub for publishing MQTT messages to the broker; and
  • mosquitto_sub for subscribing to MQTT messages distributed by the broker.

    In IOTstack, the "broker" is usually the Mosquitto container.

Assuming the Mosquitto clients are installed, you can run the following command:

$ mosquitto_sub -v -h "localhost" -t "zigbee2mqtt/#" -F "%I %t %p"

One of two things will happen:

  • silence, indicating that the Zigbee2MQTT container is not able to communicate with the Mosquitto container. If this happens, you should check the Zigbee2MQTT log.
  • chatter, proving that the Zigbee2MQTT container can communicate with the Mosquitto container.

Terminate the mosquitto_sub command with a Controlc.

Connecting to the web GUI

Open a browser, and point it to port 8080 on your Raspberry Pi. For example:

http://raspberrypi.local:8080

You should see the Zigbee2MQTT interface.

Notes:

  1. The availability of the Zigbee2MQTT UI is governed by an environment variable. If you do not see the UI, check that … FRONTEND is defined.

  2. In the URL above, port 8080 is an external port which is exposed via the following port mapping in the Zigbee2MQTT service definition:

    ports:
      - "8080:8080"
    

    If you want to reach the Zigbee2MQTT UI via a different port, you should edit the left hand side of that mapping. For example, if you wanted to use port 10080 you would write:

    ports:
      - "10080:8080"
    

    Do not change the internal port number on the right hand side of the mapping. To apply changes to the port mapping:

    $ cd ~/IOTstack
    $ docker-compose up -d zigbee2mqtt
    

Shell access to the container

To open a shell inside the Zigbee2MQTT container, run:

$ docker exec -it zigbee2mqtt ash

ash is not a typo!

To close the shell and leave the container, either type "exit" and press return, or press Controld.

Container maintenance

When you become aware of a new version of Zigbee2MQTT on DockerHub, do the following:

$ cd ~IOTstack
$ docker-compose pull zigbee2mqtt
$ docker-compose up -d zigbee2mqtt
$ docker system prune

In words:

  1. Be in the correct directory.
  2. The pull compares the version on your Raspberry Pi with the latest version on DockerHub, and downloads any later version.
  3. If a newer version is downloaded, the up instantiates a new container based on the new image and performs a new-for-old swap. There is barely any downtime.
  4. The prune cleans up the older image.

You can omit the zigbee2mqtt arguments from the pull and up commands, in which case docker-compose makes an attempt to pull any available updates for all non-Dockerfile-based images, and then instantiates any new images it has downloaded.

Service definition change

This information is for existing users of the Zigbee2MQTT container.

The default IOTstack service definition for Zigbee2MQTT has changed:

  • The container no longer needs to be built using a Dockerfile.
  • The Zigbee2MQTT images on DockerHub can be used "as is".
  • Environment variables supplied with the updated service definition exactly replicate the purpose of the old Dockerfile.
  • The Dockerfile supplied with the IOTstack template is deprecated but continues to be provided to maintain backwards compatibility and to avoid introducing a breaking change.

If you were using the Zigbee2MQTT container in IOTstack before April 2022, you should use your favourite text editor to update your compose file to conform with the new service definition.

You could run the menu, then de-select and re-select Zigbee2MQTT. That will have the effect of applying the updated service definition but it also risks overwriting any other customisations you may have in place. That is why editing your compose file is the recommended approach.

The updated service definition is included here for ease of reference:

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
zigbee2mqtt:
  container_name: zigbee2mqtt
  image: koenkk/zigbee2mqtt:latest
  environment:
    - TZ=${TZ:-Etc/UTC}
    - ZIGBEE2MQTT_CONFIG_MQTT_SERVER=mqtt://mosquitto:1883
    - ZIGBEE2MQTT_CONFIG_FRONTEND=true
    - ZIGBEE2MQTT_CONFIG_ADVANCED_LOG_SYMLINK_CURRENT=true
    # - DEBUG=zigbee-herdsman*
  ports:
    - "8080:8080"
  volumes:
    - ./volumes/zigbee2mqtt/data:/app/data
  devices:
    - "${ZIGBEE2MQTT_DEVICE_PATH:?eg echo ZIGBEE2MQTT_DEVICE_PATH=/dev/ttyACM0 >>~/IOTstack/.env}:/dev/ttyACM0"
  restart: unless-stopped
  depends_on:
    - mosquitto

The changes you should make to your existing Zigbee2MQTT service definition are:

  1. Replace the build directive:

    build: ./.templates/zigbee2mqtt/.
    

    with this image directive:

    image: koenkk/zigbee2mqtt:latest
    

    This causes IOTstack to use Zigbee2MQTT images "as is" from DockerHub.

  2. Add these environment variables:

      - ZIGBEE2MQTT_CONFIG_MQTT_SERVER=mqtt://mosquitto:1883
      - ZIGBEE2MQTT_CONFIG_FRONTEND=true
      - ZIGBEE2MQTT_CONFIG_ADVANCED_LOG_SYMLINK_CURRENT=true
    

    The first two have the identical effect to the changes previously made via the Dockerfile. The last variable makes it easier for you to find and view the current log.

    See environment variables for more detail.

  3. Add the dependency clause:

    depends_on:
      - mosquitto
    

    This ensures the Mosquitto container is brought up alongside Zigbee2MQTT. The Zigbee2MQTT container goes into a restart loop if Mosquitto is not reachable so this change enforces that business rule. See … MQTT_SERVER for the situation where this might not be appropriate.

pre-existing configuration file

Environment variables in your compose file override corresponding values set in the configuration file at:

~/IOTstack/volumes/zigbee2mqtt/data/configuration.yaml

If you have customised your existing Zigbee2MQTT configuration file, you should review your settings for potential conflicts with the environment variables introduced by the changes to the IOTstack service definition. You can resolve any conflicts either by:

  • removing or commenting-out conflicting environment variables; or
  • altering the environment variable values to match your configuration file.

The second approach is recommended because it minimises the risk that Zigbee2MQTT will go into a restart loop if the configuration file is not present when the container starts.

As the Zigbee2MQTT documentation explains, any option that can be set in a configuration file can also be set using an environment variable, so you may want to take the opportunity to implement all your settings as environment variables.